Skip to product information
Woodpecker Implanter Optic – main unit

Precise motor for dental implants.

4.3
(79)
Rs. 185,000.00
Taxes included. Shipping calculated at checkout.

What's Inside

1 items
FREE Delivery
Jun 30 - Jul 05
Order within
-- h : -- m

HUMAN SKIN LIKE

Same day Shipping

READY TO USE

Beginer Friendly

Key Specifications

Rotation Speed Range - 300 - 40000rpm
Torque Range/Gear 20:1 - 5N.cm- 80Ncm
Max Pump Output - 110ml/min
Main Unit Dimensions - φ23.4mm*L91mm
Motor Weight - 140g
Power Supply - Ac220v 50/60Hz
Device for intermittent operation: 3 min ON,10 min OFF
Power supply voltage: 200-240V~
Power supply frequency: 50/60Hz
Software version: Implant-V1
Input power: 150VA
Fuses: 2×T1.6AL 250V
Applied parts: Contra-angle handpiece
Maximum Temperature: 41.8℃
Maximum water volume: 135ml/min
Dimension: 276mm*267mm*110mm
Environment temperature: +5~40℃
Relative humidity: 30%~75%
Atmosphere pressure:70kPa~106kPa
Device case material: PC+ABS
Handpiece material: brass
Storage: Store in a clean, dry, ventilated, non-corrosive atmosphere with a relative humidity of 10% to 93%, an atmospheric pressure of 70KPa to 106KPa, and a temperature of -20 °C to +55 °C;

Direction To Use

Preparation:

  • Ensure that the device is connected to a grounded electrical outlet.
  • Verify that the cabling system meets the appropriate standards and requirements.
  • Check that all accessories and components are properly assembled and in good working condition.
  • Inspect the handpiece and cables for any signs of damage or wear.

Power On:

  • Turn on the power supply to the Implanter Optic.
  • The device will initiate the start-up process, and the color touch screen will display the main interface.

Setting Parameters:

  • Navigate the menu options on the touch screen using the intuitive user interface.
  • Adjust the necessary parameters for the specific implant surgery, such as speed and torque settings, using the preset values or manual input.
  • Ensure that the parameters are appropriate for the patient and the specific dental implant procedure being performed.

Patient Preparation:

  • Follow standard protocols for patient preparation, including proper disinfection and sterilization techniques.
  • Position the patient comfortably in the dental chair, ensuring proper access to the treatment area.

Operating the Implanter Optic:

  • Hold the contra-angle handpiece securely and place it in the patient's mouth.
  • Activate the foot pedal to initiate the operation.
  • Monitor the device's performance on the touchscreen display, ensuring that the parameters remain within the desired range.
  • Follow the recommended operating times and intervals to prevent overheating or system malfunction.

Cleaning and Maintenance:

  • After each use, power off the Implanter Optic and disconnect it from the power supply.
  • Clean and disinfect the handpiece and other reusable components according to the manufacturer's instructions.
  • Wipe the control panel and touch the screen with a damp cloth, avoiding any corrosive solutions.
  • Store the device in a clean, dry, and well-ventilated area, following the recommended storage conditions.
Packaging
{"type":"root","children":[{"type":"list","listType":"unordered","children":[{"type":"list-item","children":[{"type":"text","value":"1 x Physiodispenser"}]},{"type":"list-item","children":[{"type":"text","value":"1 x Handpiece"}]},{"type":"list-item","children":[{"type":"text","value":"1 x Foot Pedal with cable"}]},{"type":"list-item","children":[{"type":"text","value":"1 x Handpiece Stand"}]}]}]}
Additional Info

Country of Origin: PRC
Manufacturer: Woodpecker

Payment Options

COD
Net Banking
UPI
Wallet
Cards
EMI

AeDental Benefits

Free
Shipping
Hassle Free
Cancellation
10 Days
Replacement
100%
Genuine

Got Any Doubts?

What is the motor's speed and torque range?

The motor has a rotation speed range of 300 to 40,000 rpm. When using a 20:1 gear, the torque range is 5 N.cm to 80 N.cm.

Are there any limits on continuous operation?

Yes, this device is designed for intermittent operation. It should be used for a maximum of 3 minutes on, followed by a 10 minute off period.

What are the recommended storage conditions?

The device should be stored in a clean, dry, and ventilated environment at a temperature between -20°C and +55°C. The relative humidity should be between 10% and 93%.

What materials are used for the case and handpiece?

The device case is constructed from PC+ABS material. The handpiece is made of brass.

What is the maximum output of the irrigation pump?

The irrigation pump has a maximum output of 110 ml/min to ensure optimal cooling.

Related Products