Key Specifications

Compliance: Directive 93/42EEC
Ingress Protection Rating: Device: IPX1, Foot Pedal: IPX6 (EN60529)
Software Version: BoneSurgical4-V1.0.0
Operation Cycle: 60 seconds ON, 10 seconds OFF
Power-Supply Voltage: ~100V-240V, 50Hz/60Hz
Power Consumption: 170VA
Fuses: 2×1.6AT, 250V
Working Frequency: 24kHz~36kHz
Flow: 25~110ml/min
Applied Parts: Tips
Additional Features: Sterilizable water pipe, Multi-function foot pedal, Ultra-quiet peristaltic pump
Usage- In oral and maxillofacial surgery
Contra Indication: Do not use the Surgic smart on patients with pace-makers or other implantable electronic devices. The same requirement applies also to the operator.
An electrosurgical knife could interfere with correct functioning of the device.

Direction To Use

Setup and Preparations:

  • Ensure the unit is placed on a stable surface near the dental workstation.
  • Connect the power supply to the unit and plug it into a suitable electrical outlet (100V-240V, 50Hz/60Hz).
  • Check that the foot pedal is connected securely to the unit.
  • Fill the water reservoir with a suitable sterile saline solution.
  • Insert the desired tip securely into the handpiece.

Power On:

  • Switch on the Surgic Smart Piezosurgery Unit using the power button.
  • Verify that the unit displays the correct software version (BoneSurgical4-V1.0.0).

Adjust Settings:

  • Set the desired operational mode on the control panel, if applicable.
  • Adjust the power level using the appropriate controls.

Sterilization:

  • Ensure that the applied parts (tips) are properly sterilized before use. Follow recommended sterilization protocols.

Positioning and Operation:

  • Position the handpiece with the selected tip in the desired area for the surgical procedure.
  • Use the multi-function foot pedal for control. Press to activate and release to deactivate.

Perform the Procedure:

  • Apply gentle pressure and move the handpiece in a controlled manner over the target area.
  • Monitor the progress of the procedure and adjust settings as needed.

Monitor Water Flow:

  • Ensure a steady flow of water to the tip for cooling and irrigation during the procedure. Adjust as necessary.

Post-Procedure:

  • After completing the procedure, switch off the unit using the power button.
  • Disconnect the handpiece and remove the used tip for proper disposal or re-sterilization.

Cleaning and Maintenance:

  • Clean the handpiece and unit according to the manufacturer's guidelines.
  • Empty and clean the water reservoir after each use.

Shutdown:

  • Switch off the Surgic Smart Piezosurgery Unit and unplug it from the electrical outlet.
Packaging
  • 1 x Device
  • 1 x Multi-function foot pedal
  • 2 x Brine bottle connector
  • 1 x Hook
  • 8 x Pump tube
  • 1 x Peristaltic pump
  • 2 x Surgic smart handpiece
  • 2 x Silicone handpiece holder
  • 4 x Connection for the cord and tube of the peristaltic pump
  • 1 x Torque wrench
  • 2 x Sterilize box
  • 1 x Power-supply cable
Additional Info

Country of Origin: PRC
Manufacturer: Woodpecker

Payment Options

COD
Net Banking
UPI
Wallet
Cards
EMI

AeDental Benefits

Free
Shipping
Hassle Free
Cancellation
10 Days
Replacement
100%
Genuine

Got Any Doubts?

What are the clinical applications for this piezosurgery unit?

This unit is intended for use in oral and maxillofacial surgery. It features five operating modes for bone, perio, endo, implanon, and restore procedures, covering a wide range of bone surgery operations.

What are the key operating specifications of this device?

The device has a working frequency of 24kHz to 36kHz and a peristaltic pump flow rate of 25 to 110 ml/min. It is compatible with a power supply of ~100V-240V at 50Hz/60Hz.

How should the handpiece be sterilized?

The handpiece is detachable and designed to be sterilized in an autoclave. The specified temperature for autoclaving is 134℃.

Are there any contraindications for using this device?

Yes, this device must not be used on patients with pacemakers or other implantable electronic devices. This contraindication also applies to the operator, and an electrosurgical knife may interfere with the unit's function.

What is the recommended duty cycle during operation?

The recommended operation cycle for this unit is 60 seconds of continuous use followed by a 10-second rest period.